24kv Indoor Air-Compression Load Break Switch for High Voltage Applications

Type: High-voltage
Structure: Three-column Disconnector
Installation: Indoor High-voltage
Operation: Electric
Number of Poles: Three Pole
Series: Three
Samples:
US$ 1400/pcs 1 pcs(Min.Order)
| Request Sample
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (26)
  • Overview
  • General description
  • Main technical parameter
  • International fairs
  • Company show
Overview

Basic Info.

Model NO.
VACF12-24
Structure of Operating
Electric
Certification
CE, ISO9001
Brand
Vacem
Rated Current
630A
Rated Cable Charging Breaking Current
16A
Mechanical Life
2000times
Rated Service Break Current
1050A
Maximum Rated Current of Fuse
80A
Transport Package
Carton
Specification
VACF12-24
Trademark
VACEM
Origin
Wenzhou, China

Product Description

General description

The VACF12-24KV series Medium Voltage (M.V.) air type load switch and its combination apparatus are specifically designed for indoor M.V. switchgear operating at AC 24kv and 50Hz. This load switch boasts high technical parameters and reliable performance. The operating mechanism is primarily manual spring energy storage type, but it can also be equipped with an electromagnetic spring operating mechanism. Thanks to its air pressure arc extinguishing principle, the load switch can be used multiple times without the need to replace the arc extinguishing tube.
Under normal circuit conditions, the M.V. load switch can effortlessly turn on, carry, and turn off load current. It also has the capability to handle short-circuit current and withstand short-circuit current for a specified duration. This makes the M.V. load switch suitable for installation in ring network switch cabinets and other types of switch cabinets used for receiving and distributing electric energy.

Additionally, the VACF 12-24KV series load switch can be equipped with a grounding switch. This grounding switch possesses the same short-circuit closing capacity as the load switch, ensuring enhanced safety and functionality.
Main technical parameter

 

Item Unit Data
Rated voltage kV 24
Rated frequency Hz 50
Rated current A 630
Maximum rated current of fuse A 80
Rated active load breaking current A 630
Rated closed-loop breaking current rated short-time withstand current(2s) kA 20
Rated short-circuit making current,rated peak withstand current kA 50
1 min power frequency withstand voltage,phase to phase and to ground/fracture kA 65/79
Lightning impulse withstand voltage(peak value) phase to phase and to ground/break kV 125/145
Rated cable charging breaking current A 16
Mechanical life times 2000
Rated service break current A 1050
Rated short circuit breaking current of fuse kA 31.5
Phase distance mm 300±3
Total stroke of conducting rod mm 290±5
Opening distance between dynamic and static arc contact at opening position mm >215
Electric contact overtravel of moving contact rod mm 42±3
Loop resistance μΩ ≤300
 
International fairs

 

24kv Indoor Air-Compression Load Break Switch for High Voltage Applications
Company show

 

24kv Indoor Air-Compression Load Break Switch for High Voltage Applications24kv Indoor Air-Compression Load Break Switch for High Voltage Applications24kv Indoor Air-Compression Load Break Switch for High Voltage Applications24kv Indoor Air-Compression Load Break Switch for High Voltage Applications24kv Indoor Air-Compression Load Break Switch for High Voltage Applications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now