Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 500/pcs
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the game-changing 12kv High Voltage Boundary Load Break Switch for Outdoor Use! Get ready to revolutionize your power distribution system with this cutting-edge product. Designed to tackle the most challenging situations, this load break switch is a game-changer in the industry.
This high voltage load break switch is engineered with precision and expertise to deliver exceptional performance. It is specifically designed for outdoor use, making it perfect for a wide range of applications. Whether you need it for industrial purposes or residential settings, this load break switch is your ultimate solution.
With its advanced technology and robust construction, this load break switch guarantees reliability and durability. It can withstand even the harshest weather conditions, ensuring an uninterrupted power supply in any environment. You can trust this product to deliver outstanding performance year after year.
Installation is a breeze with our load break switch. It is designed for easy setup and hassle-free operation. You don't need to be an expert to get it up and running. Simply follow the user-friendly instructions, and you'll have a fully functional load break switch in no time.
Don't settle for subpar products when it comes to your power distribution system. Choose the 12kv High Voltage Boundary Load Break Switch for Outdoor Use and experience the difference.
Automatically cut single-phase earthing fault: when the user tributary line cause a single-phase earthing fault, the boundary switch will open automatically, and other distribution line users of the substation and feeding line will be without influence; isolation interphase short circuit fault automatically.
When the tributary line cause interphase short-circuit fault, the boundary switch will open at once after out-wire protection tripping. After the substation recloses, the fault line is isolated passively, and other distribution users in the feeding line resume power supply rapidly(equal to a transient fault).
Quick localization of fault: the tributary line fault causes boundary switch protection action, only the accident user cause a power cut, and by itself reports the fault information, the power company could dispatch a worker to live investigation; if the boundary switch match with a communication module, it could transmit a message to the electricity management center.
Monitoring user's load, the boundary switch could configure wired or wireless communication enclosure to monitor data and transmit it to the electricity management center, making the achievement of real-time data monitoring of users' load over long distances.
The function of a network running, could be used in network lines, the function of measurement, monitor voltage, current, frequency, and quantity of electricity of lines, and transmit to the management center in long distance. The function of harmonic analyzing is to supply a reliable basis for pollution administration of electricity net afterward.
a.Altitude:≤2000m c.Max. wind speed:≤25m/s e.Max. day temperature gap:25ºC
b.Relative humidity:≤90% d.Ambient temperature:-40ºC~85ºC f.Max. ice-covering thickness:10 mm
Item | Unit | FZW28-12F |
Rated voltage | kV | 12 |
Power frequency withstand voltage(phase to phase,to earth/fracture) | kV | 42/48 |
Power impulse withstand voltage(phase to phase,to earth/fracture) | kV | 75/85(peak) |
Rated current | A | 630 |
Rated short time withstand current | kA | 16 |
Rated thermal stability current | s | 2 |
Rated short circuit making current (peak) | kA | 40 |
Rated dynamic stability current (peak) | kA | 40 |
Rated cable charged breaking time | A | 20 |
Rated switching no-load transformer induction current | A | <5 |
Mechanical life time | time | 1,0000 |
Item | FDR-100(CH-40) |
Input operation voltage | AC220±20% |
Input operation voltage frequency | 50Hz |
Output voltage (opening) | DC220V,DC48V |
Inter-phase short circuit protection current setting value | 0.2,0.4,0.6,0.8,1.0,A5 section switching |
Earthing protection zero-order current setting value | 10~200mA 20 section switching,differential 10mA |
Earthing protection time setting value | 0.2,0.4,0.6,0.8,1.0,S6 section switching |
Setting value error | ±5% |
Insulation impedance (outer terminal to earth input terminal,to output terminal) | >100MΩ/DC500V |
P.F. withstand voltage (outer terminal to earth input terminal,to output terminal) | 2000V/1min |
Impulse withstand voltage(outer terminal to earth input terminal,to output terminal) | 5000V,1.2/50μ each 3 times of plus and minus |