Overview

Basic Info.

Model NO.
VACF25-12D/T630-20
Installation
Indoor High-voltage
Operation
Electric
Number of Poles
Three Pole
Series
Three
Structure of Operating
Electric
Certification
CE, ISO9001
Brand
Vacem
Rated Dynamic Stability Current(Peak)
50ka
4s Thermal Stability Current
20ka
Rated Power Load Breaking Current
630A
Rated Cable Charge Breaking Current
10A
Mechanical Life
6000times
Transport Package
Carton
Specification
Air-insulated switch, Electrical switchgear, Mediu
Trademark
VACEM
Origin
Wenzhou, China

Product Description

General description

Introducing the 12kv Air-Compression Load Break Switch for High Voltage Indoor Use - the ultimate solution for your industry and mining needs! This Load Break Switch is designed to provide you with the best performance and reliability, ensuring that your operations run smoothly and efficiently.
With its cutting-edge technology and innovative design, this Indoor Load Breaker Switch is the perfect choice for those who demand the best. Its Air-Compression Load Breaker Switch feature ensures that you get the most out of your equipment, while its tri-phase AC 50Hz and rated voltage of 12kv make it suitable for a wide range of applications.
Whether you're looking for a Load Break Switch for your industrial or mining operations, this product is the perfect choice. Its VACF25-12D/T630-20 indoor AC M.V. load break switch is designed to meet the highest standards of quality and performance, ensuring that you get the best value for your money.

So why wait? Get your hands on the 12kv Air-Compression Load Break Switch for High Voltage Indoor Use today and experience the difference for yourself! With its Excited and Spirited tone, this product description is sure to grab the attention of potential buyers and make your product stand out on cross-border e-commerce platforms. Don't miss out on this amazing opportunity to take your business to the next level!

Main technical parameter

a:Main technical parameter of load break switch and combined appliance is seen in Table.1

Item Unit VACF25-12D/T630-20
Rated voltage kV 12kV
Rated frequency Hz 50Hz
Rated current A 630A
Rated insulation level  1 min P.F. withstand voltage(effective value) kV Vacuum interrupter fracture30kV
kV Phase to phase,to earth42;isolating fracture48
lightning impulse withstand voltage(peak)   Vacuum interrupter fracture60kV
  Phase to phase,to earth75;isolating fracture85
Rated dynamic stability current(peak) kA 50kA
4s thermal stability current kA 20kA
Rated power load breaking current A 630A
Rated closing loop breaking current A 630A
Rated cable charge breaking current A 10A
Rated breaking no-load transformer capacity kVA 1600kVA
Rated short-circuit making current kA 50kA
Rated dynamic stability current of earth switch kA 50kA
2s thermal stability current of earth switch kA 20kA
Rated voltage of auxiliary loop V AC/DC220,110V
Mechanical life times 6000times
b:Main technical parameter of load break switch and combined appliance is seen in Table.2
Item Unit Data
VACF25-12D/T630-20
Air distance between electrics and earth mm ≥12
Depth of conductive tube inserted into fixed contact-base mm ≥18
Opening distance of vacuum interrupter mm 6(+1,0)
Contact spring compression of vacuum interrupter mm 2(+1,0)
Average closing speed of vacuum interrupter m/s 0.6±0.2
Average opening speed of vacuum interrupter m/s 1±0.2
Closing bounce time ms ≤2
Tri-phase opening synchronous ms ≤3
Main circuit resistance μΩ ≤150
Manual operation max.torque N.m ≤160
Opening time of fuse triggering ms 30~40
Opening time of release triggering ms 40~45
c:Energy-stored motor data is seen in Table.3
Type Rated voltage(kV) Rated current(A) Rated power(W) Normal operation voltage range
66ZY-CJ01B8 DC220 0.7 70 85%~110% rated voltage
66ZY-CJ02B DC110 1.5
International fairs

 

12kv Air-Compression Load Break Switch for High Voltage Indoor Use
Company show

 

12kv Air-Compression Load Break Switch for High Voltage Indoor Use12kv Air-Compression Load Break Switch for High Voltage Indoor Use12kv Air-Compression Load Break Switch for High Voltage Indoor Use12kv Air-Compression Load Break Switch for High Voltage Indoor Use12kv Air-Compression Load Break Switch for High Voltage Indoor Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier