Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 900/pcs
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the 12kv 24kv Indoor High Voltage Load Break Switch for Switchgear, the ultimate solution for all your electrical needs! This incredible product is designed to provide you with unmatched performance and reliability, ensuring that your switchgear operates at its optimal level.
With its advanced interrupting technology, the FN18 load break switch offers a level of efficiency that is simply unparalleled. Say goodbye to those frustrating power interruptions and hello to uninterrupted power supply! This load break switch is specifically designed to handle high voltage loads, making it the perfect choice for any indoor setting.
One of the key advantages of this load break switch is its compact size. We understand that space is often a constraint in switchgear installations, which is why we have designed this product to be as compact as possible. Don't let its small size fool you though, as it packs a powerful punch when it comes to performance.
When it comes to reliability, you can trust the 12kv 24kv Indoor High Voltage Load Break Switch to deliver. We have tested and proven its dependability time and time again, ensuring that you can rely on it for all your electrical needs. Whether you are a switchgear owner or an assembler, this load break switch is the perfect choice for you.
So why wait? Upgrade your switchgear today with the 12kv 24kv Indoor High Voltage Load Break Switch for Switchgear. Experience the difference that advanced interrupting technology and proven performance can make. Don't settle for anything less than the best. Choose the load break switch that stands out from the rest. Choose the FN18 load break switch.
Item | Unit | Data | |
Rated voltage | kV | 12 | 24 |
Rated current | A | 630 | 630 |
Rated power frequency | Hz | 50/60 | 50/60 |
Rated short-circuit making current | kA Peak. | 50 | 50 |
Rated peak withstand current | kA Peak. | 50 | 50 |
Short time withstand current: 1 Sec. | kA eff. | 31.5 | 25 |
Short time withstand current: 2 Sec. | 25 | 25 | |
Short time withstand current: 3 Sec. | 20 | 16 | |
IEC 62271-105(IEC 420 1990-11)Max.breaking current in co-operation with fuses IEC 62271-105(IEC 420 1990-11) | A | 1600 | 900 |
Max.fuse current(XRNT Fuse) | A | 200 | 200 |
Rated power frequency withstand voltage (50Hz 1min) | |||
-To earth and between phase | kV | 42 | 65 |
-Between fracture | kV | 48 | 79 |
Impulse withstand voltage (1.2/50μs) | |||
-To earth and between poles | kV | 75 | 125 |
-Between fracture | kV | 85 | 145 |
Mechanical life | times | 2000 | 20 |