12kv High Voltage Single Pole Vacuum Contactor

Product Details
Customization: Available
Electricity Type: AC
Number of Pole: 1
Still deciding? Get samples of US$ 455.5/pcs
Request Sample
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
Find Similar Products
  • Overview
  • General description
  • Normal using conditions
  • Main technical parameter
  • Packaging
  • International fairs
  • Company show
Overview

Basic Info.

Model NO.
VCKG3
Phase
1
Main Circuit Rating Voltage
High Voltage
Type
Ac Contactors
Rated Operating Frequency
300 Times/H
Mechanical Life
1000000 Times
Over Travel
Min:1.2mm
Opening Time
Max:25ms
Closing Time
Max:40ms
Transport Package
Carton and Pallet
Specification
VCKG3
Trademark
VACEM
Origin
Wenzhou, China
HS Code
8535900090

Product Description

General description

Introducing our incredible 12kv High Voltage Single Pole Vacuum Contactor! Get ready to be blown away by its exceptional features and outstanding performance. This contactor is the epitome of innovation, designed with an electrically insulating frame, metal base, shaft, and crank arm. It also boasts an electromagnetic system, permanent magnet, power modules, auxiliary switches, and vacuum interrupters. 
When the control voltage is applied to the electromagnetic coil, brace yourself for the armature to drive the crutch into action, rotating and opening the main contact in the vacuum interrupter. But wait, there's more! The auxiliary switch comes into play, cutting off the power to the electromagnetic coil, and transforming it into a permanent-magnet maintenance mode. 
And that's not all! When the power is disconnected by the control circuit, get ready for the energy storage power of the power module to discharge into the electromagnetic coil, resulting in a mesmerizing degaussing effect. Brace yourself for the main contact to break under the influence of the opening spring, leaving you in awe of its flawless functionality.

So, if you're in search of a contactor that will exceed your expectations, look no further than our 12kv High Voltage Single Pole Vacuum Contactor. It's the perfect combination of power, precision, and reliability. Don't miss out on this incredible product that will revolutionize your electrical systems. Get yours today and experience the difference for yourself!

Normal using conditions

a. Environment temperature: -5ºC~+40ºC, and the average value is no more than +35ºC within 24 hours.
b. Altitude: no more than 1000m.
c. Atmospheric conditions: monthly highest humidity in the wettest month is no more than 90% and the monthly average minimum temperature shall be 25ºC. Condensation on the products due to temperature changes shall be considered.
d. Impact vibration: The place is without extensive shaking, impact, and vibration.
e. The place is without explosion hazardS, enchant gas, and sleet.
f. No rain and snow in places
g. Pollution degree: Three grade
h. Installation type: III
i. Installation condition: The slant angle between the installation surface and the vertical surface is no more than 15°. 

Main technical parameter

 

Item Unit VACG3-160~630/7.2-5 VACG3-160~630/12-5
Main circuit rated voltage kV 7.2 12
Main circuit rated  current A 160 250 400 630 160 250 400 630
Main circuit current making capacity A/100times 1600 2500 4000 6300 1600 2500 4000 6300
Main circuit make-break capacity A/25times 1280 2000 3200 5000 1280 2000 3200 5000
Maximum breaking capacity A/3times 3200 3200 4000 6300 3200 3200 4000 6300
Mechanical life times 1,000,000
Power frequency withstand voltage of main circuit kV 32 42
Power frequency withstand voltage of auxiliary circuit kV 2.5
Power frequency withstand voltage of control circuit kV 2
Rated operating frequency times/h 300
Opening time ms ≤120
Closing time ms ≤150
Clearance between open contacts mm 4±0.5 5±0.5
Over travel mm ≥1.2 ≥1.2 ≥1.2 ≥1.2 ≥1.2 ≥1.2 ≥1.2 ≥1.
Packaging

 

12kv High Voltage Single Pole Vacuum ContactorFor Vacuum Circuit Breaker, pls click:  https://china-vacem.en.made-in-china.com/product-group/roqEnxmCTUYh/Vacuum-Circuit-Breaker-catalog-1.html
International fairs

 

12kv High Voltage Single Pole Vacuum Contactor
Company show

 

12kv High Voltage Single Pole Vacuum Contactor12kv High Voltage Single Pole Vacuum Contactor12kv High Voltage Single Pole Vacuum Contactor12kv High Voltage Single Pole Vacuum Contactor12kv High Voltage Single Pole Vacuum Contactor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier