Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of US$ 1000/pcs
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the 12kv Outdoor M. V. Vacuum Circuit Breaker with Isolating Blade on Pole, the ultimate solution for all your high-voltage circuit breaking needs! This cutting-edge product is designed to provide exceptional performance and reliability in outdoor environments, making it the perfect choice for a wide range of applications.
With its advanced technology and innovative design, the 12kv Outdoor M. V. Vacuum Circuit Breaker guarantees efficient and safe operation. Equipped with a vacuum interrupter, this circuit breaker ensures a reliable and consistent breaking of load current, over-current, and short-circuit currents. Say goodbye to the worries of electrical faults and disruptions, as this circuit breaker is built to handle even the most demanding conditions.
Designed for outdoor use, this circuit breaker is built to withstand harsh weather conditions, ensuring uninterrupted power supply in any environment. Its robust construction and durable materials make it resistant to corrosion, moisture, and other environmental factors, ensuring a long service life and minimal maintenance requirements.
The 12kv Outdoor M. V. Vacuum Circuit Breaker features an isolating blade on the pole, providing an additional layer of safety and convenience. This feature allows for easy isolation of the circuit, ensuring the safety of personnel during maintenance or repair work. With this circuit breaker, you can rest assured that your operations will run smoothly and efficiently, without compromising on safety.
Item | Unit | ZW8-12(G)/630-6.3kA | ZW8-12(G)/630-12.5kA | ZW8-12(G)/630-20kA | |
Rated voltage | kV | 12 | |||
Rated current | A | 630 | |||
Rated short circuit breaking current | kA | 6.3 | 12.5 | 20 | |
Rated short circuit making current (peak) | kA | 16 | 31.5 | 50 | |
Rated peak value withstand current | kA | 16 | 31.5 | 50 | |
Rated short time withstand current | kA | 6.3 | 12.5 | 20 | |
Rated insulation level | 1min P.F. withstand voltage | kV | 42 | ||
Lightning impulse withstand voltage(peak) | kV | 75 | |||
Rated operation sequences | O-0.3s-CO-180s-CO | ||||
Mechanical life time | time | 10000 | |||
Rated short-circuit current breaking times | time | 30 | |||
Rated closing time voltage of operation mechanism | V | 110,220 | |||
Rated opening time voltage of operation mechanism | V | 110,220 | |||
Contact opening distance | mm | 11±1 | |||
Over travel (spring compressed length) | mm | 3±0.3 | |||
Tri-phase O/C asynchronous | ms | ≤2 | |||
Contact closing bounce time | ms | ≤2 | |||
Average opening speed | m/s | 1.0±0.2 | |||
Average closing speed | m/s | 0.7±0.15 | |||
Opening time | Under max operation voltage | ms | 15-50 | ||
Under min operation voltage | ms | 30-60 | |||
Closing time | ms | 25-50 | |||
Each phase main circuit resistance | μΩ | ≤120(with G≤200) | |||
Allowable attrition thickness of moving and fixed contacts | mm | 3 | |||
Weight | kg | 152(with G 180) | |||
Phases center distance | mm | 175±1.5 |