12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance

Product Details
Customization: Available
Electricity Type: AC
Number of Pole: 3
Still deciding? Get samples of US$ 9/pcs
Request Sample
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • 12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance
Find Similar Products
  • Overview
  • General description
  • Main technical parameter
  • Product show
  • International fairs
  • Company show
Overview

Basic Info.

Model NO.
TD-12/1600-31.5(VAC302)
Phase
3
Main Circuit Rating Voltage
High Voltage
Type
Ac Contactors
Power Frequency Withstand Voltage
42kv
Lightning Impulse Withstand Voltage
75kv
Mechanical Life
10000 Times
Rated Clearance Between Open Contacts
10~12mm
Rated Contact Stroke
3~4mm
Transport Package
Carton
Specification
VAC302
Trademark
VACEM
Origin
Wenzhou, China

Product Description

Vacuum interrupter for vacuum circuit breaker
TD-12/1600-31.5(VAC302)
General description

Introducing the 12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance! This cutting-edge product is the perfect solution for all your high voltage needs. With its advanced technology and superior design, this vacuum interrupter is the ultimate choice for those who demand the best.
Crafted with precision and care, this high-performance vacuum interrupter is designed to meet the highest standards of quality and reliability. It is engineered to provide exceptional performance and durability, making it the ideal choice for a wide range of applications.
Whether you are looking for a vacuum interrupter for your industrial equipment or for your power distribution system, this product is the perfect choice. It is designed to deliver outstanding performance and reliability, ensuring that your equipment operates at peak efficiency.VI is mainly used for VZN63-12kV series MV vacuum circuit breaker. Meets or exceeds the requirement of IEC62271-100 and E2 level in GB1984-2003.
With its advanced features and superior design, this vacuum interrupter is the perfect choice for those who demand the best. It is built to withstand the toughest conditions and is designed to provide long-lasting performance and reliability.

So why wait? If you are looking for a high-performance vacuum interrupter that delivers exceptional performance and reliability, look no further than the 12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance. Order yours today and experience the ultimate in high voltage technology!
Main technical parameter

Specification of VI

Parameter item Unit Data
Rated voltage kV 12
Rated current A 1600
Rated frequency Hz 50
Rated short-time power frequency withstand voltage(1 min) kV 42
Rated lightning impulse withstand voltage kV 75
Rated short-circuit breaking current kA 31.5
Rated peak withstand current kA 80
Rated short-circuit making current kA 80
Rated short-time withstand current kA 31.5
Rated short-circuit duration s 4
Rated single capacitor bank breaking current A 630
Rated back to back capacitor bank breaking current A 400
Breaking operation of rated short circuit breaking current times 30
Mechanical life times 10000
Contact closing force due to bellows and atomsphere N 125±50
Force required to hold contact open at full stroke N 200±50
Circuit resistance at lowest rated contact force μΩ ≤20
Contact limit erosion mm 3
Internal gas pressure Pa ≤1.33×10-3
Weight of moving parts kg 1.3
Storage life year 20

Specifications required for matched switchgear
Parameter item Unit Data
Rated clearance between open contacts mm 11±1
Average opening speed m/s 1.1±0.2
Average closing speed m/s 0.6±0.2
Rated contact pressure N 3100±200
Contact bouncing duration at closing operation ms ≤2
Closing and opening non-simultaneity of contacts ms ≤2
Maximum rebound during opening mm ≤2
Rated contact stroke mm 3.5±0.
Product show

 

12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance
International fairs

 

12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance
Company show

 

12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance12kv High Voltage Vacuum Interrupter for Vacuum Circuit Break - High Performance

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier